Standard Bearing Isolator on VFD motor

2018-01-19 15:00:12

Enduser: Steel Plant

Application: Blower Pillow Block

Original Seal: Labyrinth Seal

Working Condition: High Radial And Axial Shaft Movement, Heavy Contamination, forced oil lubrication system.


BRS Solution: Alluminum alloy material, split design bearing isolator, with PTFE buffer ring and locating pin


Installation Date: 2014

Peformance: No leakage, no contamination, no damage to the shaft. The blowers work with no unexpected shut-down during the period of one year between the facility maintanences.